Flow Rate & Head Height for Your Pond
Not sure? Work it out here.
Fast or slow? See the pros and cons below.
Height and pipework
From the water surface the pump draws from, up to the highest point the water is pushed to. Pump-fed: up to the filter inlet. Gravity-fed: from the filter's water level to the return (often small).
Bores are typical published figures and vary slightly by maker.
Straight runs added together. Leave blank for a pump right next to the filter.
Fittings (how many?)
For a pressurised filter, UV unit or similar: use the figure from its manual, if given.
Ready to track your pond parameters and treatments like a pro?
Try Koi Toolkit PRO →Quick answer: divide your pond volume by how often you want it to go round. A 10,000 litre pond turned over once an hour needs 10,000 litres per hour. Then work out the total head (the height the pump lifts plus the friction in your pipes) and choose a pump that still gives that flow at that height, not just the figure on the box.
A 10,000 litre koi pond, turned over every hour, pump-fed. The filter inlet is 1.2m above the pond surface, with 10m of 2″ grey pressure pipe, four 90° elbows and one non-return valve:
The same run in 1½″ pipe has about 1.6m of friction, so the total head rises to about 2.8m. That's a noticeably bigger pump for the same pond.
There's no single right answer, and opinion among koi keepers changes over time. Many keepers now run slower than the old "fast as possible" approach. Typical advice ranges from every 30 minutes (often with drum filters) to every 2 hours.
Your filter's maximum flow rating is the upper limit, whatever turnover you choose.
Pump-fed: the pump sits in the pond (or draws from it) and pushes water up into the filter. The lift is the height from the pond surface to the filter inlet.
Gravity-fed: water flows from the bottom drain into the filter under gravity, and the pump returns it to the pond. The pump only lifts from the filter's water level back to the pond, so the lift is often very small. Most of the head is pipe friction and anything fitted after the pump, such as a UV unit.
Pump makers publish a chart or table showing flow at different heights. The headline figure is at zero height. As the height goes up, the flow drops, slowly at first and then quickly. Find your total head on the chart and read across: if the flow there is at least what you need, the pump should do the job. Choose a pump that reaches your target comfortably, not one right at the end of its range.
Friction goes up very quickly as pipes get smaller or water moves faster. Going up one pipe size often makes a bigger difference than buying a stronger pump. As a guide, keep the water speed in the pump's outlet pipe to about 2 m/s or less. The pipe on the inlet side of an external pump should be larger and slower still.
| Pipe | Outside | Bore (inside) |
|---|---|---|
| 1″ grey pressure | 33.6mm | 29.2mm |
| 1½″ grey pressure | 48.3mm | 42.1mm |
| 2″ grey pressure | 60.3mm | 52.5mm |
| 40mm black waste | 43mm | 39mm |
| 50mm black waste | 56mm | 51mm |
| 110mm soil / drain | 110mm | 103.6mm |
Grey pressure pipe is named by its approximate bore; waste pipe by its approximate size. The two systems don't fit each other: 1½″ pressure pipe and 40mm waste pipe have different outside diameters. Waste pipe isn't made for pressure, so check it's suitable for where you use it.
Each fitting adds friction equal to a length of straight pipe. This calculator uses standard engineering values (from Crane's Flow of Fluids, the long-standing reference), counted in pipe diameters:
So a single 90° elbow in 2″ pipe adds roughly the friction of 1.6m of straight pipe. Swept bends and fewer fittings keep the flow up, and they also help stop debris collecting.
A pump runs 24 hours a day, so its wattage matters as much as its price. Once you've picked a pump, the energy calculator works out what it will cost to run.
This calculator uses standard formulas and typical figures for smooth plastic pipe, so treat the result as a good starting point rather than an exact answer. Real systems vary because of:
If in doubt, choose a pump with some headroom, or one with adjustable speed, and ask your supplier to check it against the maker's chart.