Every calculator on Koi Pond Toolkit runs on your own phone or computer. Nothing you type is sent anywhere. This page shows the formula behind each one, where it comes from, and who has checked it, so you can check the numbers yourself.
Independent review
In February 2026, Syd Mitchell (mankysanke.co.uk), a Water Quality Instructor with Koi Organisation International, reviewed the original ten calculators. He stress-tested them, checked the equations against aquaculture engineering research and first principles, and sent me what he found. I fixed every point he raised, and finished on 13 February 2026.
The ten calculators he reviewed are ammonia, KH, sodium thiosulfate, vitamin C, salt, bio media, pond volume, pipe volume, trickle and energy. Each one shows a green "✓ Calculations validated" line under its title.
Since then I've added dose tables, worked examples, a salt bath mode and an oval shape on the volume calculator. These use the same formulas he checked, apart from the oval, which uses the standard formula for an ellipse. In November 2026 I also updated two bio media ratings to match the manufacturers' published figures.
The pond liner and pump size calculators were added in November 2026 and haven't been independently reviewed, which is why they don't show the green line. They use standard engineering formulas, listed below.
Water quality
Ammonia (free ammonia, NH₃)
- Most test kits measure total ammonia (TAN). Only part of it is the toxic free ammonia, and how much depends on pH and temperature.
- Formula: pKa = 0.09018 + 2729.92 ÷ (temperature °C + 273.15). Free ammonia = TAN × 1 ÷ (1 + 10(pKa − pH)).
- Source: Emerson et al. (1975), the standard equation used in aquaculture.
- Traffic lights: green below 0.02 mg/l, amber 0.02–0.04 mg/l, red above 0.04 mg/l.
KH buffer (sodium bicarbonate / baking soda)
- 30 g of sodium bicarbonate per 1,000 litres raises KH by 1 dKH (1 dKH = 17.848 mg/l).
- If you need to raise KH by more than about 20 mg/l (1.13 dKH), the calculator splits the dose over several days to avoid a sudden pH swing.
Sodium thiosulfate dechlorinator
- 4 g of sodium thiosulfate (pentahydrate crystals) per 1,000 litres for every 1 mg/l of total chlorine.
- The standard reaction needs about 3.5 times the chlorine reading. The calculator uses 4 times to make sure all the chlorine is neutralised, without leaving a large excess.
Sodium thiosulfate calculator →
Vitamin C dechlorinator (sodium ascorbate)
- 2.8 mg of sodium ascorbate per 1 mg of chlorine, plus a 10% safety margin.
- Example: 2,000 litres at 1 mg/l is 2,000 mg of chlorine, so 2,000 × 2.8 × 1.1 = 6.2 g.
Salt (salinity)
- 1 kg of pure salt per 1,000 litres raises salinity by 0.1% (1 g per litre = 0.1%).
- The salt bath mode uses the same relationship for whatever concentration you enter. The calculator doesn't suggest strengths or times.
- Assumes pure dried vacuum (PDV) salt with no additives.
Bio media
- Media needed = grams of food per day ÷ how much food a litre of mature media can handle.
- The ratings come from the manufacturers' published figures: K1 5 g per litre (Evolution Aqua: 50 litres handles 250 g a day), Hel-X 13 6.8 g (OASE: 25 litres handles 170 g), original Hel-X 6 g (OASE: 50 litres handles about 300 g), and PondPads 21.5 g (OASE: 10 litres handles about 215 g).
- K1 Micro has no published rating, so 9 g per litre is our estimate, based on its surface area compared with K1.
- These are ratings for fully mature media in warm water. Cold water or a new filter handles less, so allow 20–30% extra.
Volumes and flow
Pond volume
- Rectangle: length × width × average depth (metres) × 1,000 = litres.
- Round: π × radius² × depth × 1,000.
- Oval: length × width × depth × π ÷ 4 × 1,000.
- Gallons: 1 UK gallon = 4.546 litres; 1 US gallon = 3.785 litres.
Pipe volume
- π × (internal bore ÷ 2)² × length, using the real internal bore of each pipe type rather than its nominal size.
Trickle and water change plan
- Weekly change = pond volume × the percentage you choose. Spread evenly, that's the weekly volume ÷ 7 days ÷ 1,440 minutes per day.
Pond liner (not yet independently reviewed)
- Planning mode: liner length = pond length + 2 × deepest depth + 2 × overlap (and the same for width). This assumes straight sides, so it gives the maximum you could need. Round ponds need a square liner.
- Already-dug mode: run a tape along the ground across the pond, then add 2 × overlap. This is better for bowls and sloping sides, where the formula can oversize by up to about a third.
- Default overlap is 50 cm a side. Results round up to the next 0.5 m (or 1 ft).
Pump size (not yet independently reviewed)
- Flow needed = pond volume ÷ turnover time (you choose; the default is once an hour).
- Total head = vertical lift + pipe friction + fittings.
- Pipe friction uses the Hazen-Williams equation (C = 150 for smooth plastic pipe), with real internal bores.
- Fittings use equivalent-length factors from Crane Technical Paper 410: 90° elbow 30, swept bend 20, 45° bend 16, ball valve 3, non-return valve 50 (multiplied by the pipe bore).
- Spot check: 2″ pipe at 3,000 US gallons per hour gives 3.97 ft of friction per 100 ft, against about 4 in published tables.
- The result is a starting point, not a guarantee. Always check the pump maker's flow-versus-head chart.
Running costs
Energy
- kWh per day = watts × hours ÷ 1,000. Cost = kWh × your price per kWh. A month is taken as 30.41 days (365 ÷ 12).
What the calculators don't do
- They don't replace a vet. If your fish are unwell, speak to a fish vet or an experienced keeper.
- They're only as accurate as your readings. Test kits vary, so an accurate volume and a good test kit matter most.
- Always dose in stages and re-test.
Spotted a mistake?
If a number doesn't look right, please email support@koipondtoolkit.uk. I'd rather know.